Preliminary development of mini anechoic chamber

The purpose of mini anechoic chamber is to allow cost effective testing of microwave signal. It is because measurements of the radiation pattern are usually done in an anechoic chamber in order to avoid reflections from nearby objects and external interference from affecting the field pattern. The m...

Full description

Bibliographic Details
Published in:2007 Asia-Pacific Conference on Applied Electromagnetics Proceedings, APACE2007
Main Author: Hasnain A.; Imran M.I.; Rohaiza Z.S.; Roslan S.; Takiyuddin A.A.; Rusnani A.; Azremi A.A.
Format: Conference paper
Language:English
Published: 2007
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-52949089360&doi=10.1109%2fAPACE.2007.4603965&partnerID=40&md5=6e1b1e7c7e94af54e957a134803d0cf4
id 2-s2.0-52949089360
spelling 2-s2.0-52949089360
Hasnain A.; Imran M.I.; Rohaiza Z.S.; Roslan S.; Takiyuddin A.A.; Rusnani A.; Azremi A.A.
Preliminary development of mini anechoic chamber
2007
2007 Asia-Pacific Conference on Applied Electromagnetics Proceedings, APACE2007


10.1109/APACE.2007.4603965
https://www.scopus.com/inward/record.uri?eid=2-s2.0-52949089360&doi=10.1109%2fAPACE.2007.4603965&partnerID=40&md5=6e1b1e7c7e94af54e957a134803d0cf4
The purpose of mini anechoic chamber is to allow cost effective testing of microwave signal. It is because measurements of the radiation pattern are usually done in an anechoic chamber in order to avoid reflections from nearby objects and external interference from affecting the field pattern. The most important element in anechoic chamber is absorber. The electromagnetic wave absorbers are used to absorb the reflected wave that occurs on the wall of the chamber. A good absorber is the one with smaller reading of reflection wave. The operation of absorber depends on the design and the material used. This project focused on the development and designs the absorbers for anechoic chamber. There were then assembled into a chamber for further Testing.. © 2007 IEEE.


English
Conference paper

author Hasnain A.; Imran M.I.; Rohaiza Z.S.; Roslan S.; Takiyuddin A.A.; Rusnani A.; Azremi A.A.
spellingShingle Hasnain A.; Imran M.I.; Rohaiza Z.S.; Roslan S.; Takiyuddin A.A.; Rusnani A.; Azremi A.A.
Preliminary development of mini anechoic chamber
author_facet Hasnain A.; Imran M.I.; Rohaiza Z.S.; Roslan S.; Takiyuddin A.A.; Rusnani A.; Azremi A.A.
author_sort Hasnain A.; Imran M.I.; Rohaiza Z.S.; Roslan S.; Takiyuddin A.A.; Rusnani A.; Azremi A.A.
title Preliminary development of mini anechoic chamber
title_short Preliminary development of mini anechoic chamber
title_full Preliminary development of mini anechoic chamber
title_fullStr Preliminary development of mini anechoic chamber
title_full_unstemmed Preliminary development of mini anechoic chamber
title_sort Preliminary development of mini anechoic chamber
publishDate 2007
container_title 2007 Asia-Pacific Conference on Applied Electromagnetics Proceedings, APACE2007
container_volume
container_issue
doi_str_mv 10.1109/APACE.2007.4603965
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-52949089360&doi=10.1109%2fAPACE.2007.4603965&partnerID=40&md5=6e1b1e7c7e94af54e957a134803d0cf4
description The purpose of mini anechoic chamber is to allow cost effective testing of microwave signal. It is because measurements of the radiation pattern are usually done in an anechoic chamber in order to avoid reflections from nearby objects and external interference from affecting the field pattern. The most important element in anechoic chamber is absorber. The electromagnetic wave absorbers are used to absorb the reflected wave that occurs on the wall of the chamber. A good absorber is the one with smaller reading of reflection wave. The operation of absorber depends on the design and the material used. This project focused on the development and designs the absorbers for anechoic chamber. There were then assembled into a chamber for further Testing.. © 2007 IEEE.