Cable test and breakdown voltage determination of Joysense cable insulation

Cross-linked Polyethylene (XLPE) has been used as the insulation for polymeric power cables for its superior advantages. This type of cable insulation are famously known and used for their good dielectric properties, mechanical properties, thermal properties, and probability to be utilized at high t...

Full description

Bibliographic Details
Published in:Indonesian Journal of Electrical Engineering and Computer Science
Main Author: bin Yahya M.; bin Izani M.N.A.
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2017
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85037650407&doi=10.11591%2fijeecs.v8.i1.pp177-183&partnerID=40&md5=eefa4ec9748bc1ba609ead8e3e9de557
Description
Summary:Cross-linked Polyethylene (XLPE) has been used as the insulation for polymeric power cables for its superior advantages. This type of cable insulation are famously known and used for their good dielectric properties, mechanical properties, thermal properties, and probability to be utilized at high temperature. This study is of four (4) parts; designing suitable method for cable test, accelerated testing procedures applied to XLPE insulation for high voltage cables, online partial discharge determination, and aging test. To study the insulation durability to AC high voltage operation, the breakdown strength and aging were investigated under different setting of temperature. The breakdown voltages of XLPE were measured at different temperatures of 300C, 500C and finally at 700C. Lastly, the aging effect of cable insulation was observed by conducting the AC breakdown voltage test after the aging process. Results showed that the breakdown voltage and aging of XLPE cables will decrease with increase of temperature setting. © 2017 Institute of Advanced Engineering and Science. All rights reserved.
ISSN:25024752
DOI:10.11591/ijeecs.v8.i1.pp177-183