Electrochemical stability of PEDOT for wearable on-skin application
Conducting polymers are promising candidates for wearable devices due to mechanical flexibility combined with electroactivity. While electrochemical measurements have been adopted as a central transduction method in many on-skin sensors, less studied is the stability of the active materials (in part...
Published in: | Journal of Applied Polymer Science |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
John Wiley and Sons Inc
2021
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85108782114&doi=10.1002%2fapp.51314&partnerID=40&md5=4c6e54242bb99c5c962806f6e32851a5 |
id |
2-s2.0-85108782114 |
---|---|
spelling |
2-s2.0-85108782114 Ajmal Mokhtar S.M.; Alvarez de Eulate E.; Sethumadhavan V.; Yamada M.; Prow T.W.; Evans D.R. Electrochemical stability of PEDOT for wearable on-skin application 2021 Journal of Applied Polymer Science 138 44 10.1002/app.51314 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85108782114&doi=10.1002%2fapp.51314&partnerID=40&md5=4c6e54242bb99c5c962806f6e32851a5 Conducting polymers are promising candidates for wearable devices due to mechanical flexibility combined with electroactivity. While electrochemical measurements have been adopted as a central transduction method in many on-skin sensors, less studied is the stability of the active materials (in particular poly3,4-ethylenedioxythiophene, PEDOT) in such systems, particularly for “on-skin” applications. In this study, several different variants of doped PEDOT are fabricated and characterized in terms of their (electrical, physical, and chemical) stability in biological fluid. PEDOT doped with tosylate (TOS) or polystyrenesulfonate (PSS) are selected as prototypical forms of conducting polymers. These are compared with a new variant of PEDOT co-doped with both TOS and PSS. Artificial interstitial fluid (aISF) loaded with 1% wt/vol bovine serum albumin is adopted as the testing medium to demonstrate the stability in dermal applications (i.e., conducting polymer microneedles or coatings on microneedles). A range of techniques such as cyclic voltammetry and electrochemical impedance spectroscopy are used to qualify and quantify the stability of the doped conducting polymers. Furthermore, this study is extended by using human skin lysate in the aISF to demonstrate proof-of-concept for stable use of PEDOT in wearable “on-skin” electronics. © 2021 The Authors. Journal of Applied Polymer Science published by Wiley Periodicals LLC. John Wiley and Sons Inc 218995 English Article All Open Access; Hybrid Gold Open Access |
author |
Ajmal Mokhtar S.M.; Alvarez de Eulate E.; Sethumadhavan V.; Yamada M.; Prow T.W.; Evans D.R. |
spellingShingle |
Ajmal Mokhtar S.M.; Alvarez de Eulate E.; Sethumadhavan V.; Yamada M.; Prow T.W.; Evans D.R. Electrochemical stability of PEDOT for wearable on-skin application |
author_facet |
Ajmal Mokhtar S.M.; Alvarez de Eulate E.; Sethumadhavan V.; Yamada M.; Prow T.W.; Evans D.R. |
author_sort |
Ajmal Mokhtar S.M.; Alvarez de Eulate E.; Sethumadhavan V.; Yamada M.; Prow T.W.; Evans D.R. |
title |
Electrochemical stability of PEDOT for wearable on-skin application |
title_short |
Electrochemical stability of PEDOT for wearable on-skin application |
title_full |
Electrochemical stability of PEDOT for wearable on-skin application |
title_fullStr |
Electrochemical stability of PEDOT for wearable on-skin application |
title_full_unstemmed |
Electrochemical stability of PEDOT for wearable on-skin application |
title_sort |
Electrochemical stability of PEDOT for wearable on-skin application |
publishDate |
2021 |
container_title |
Journal of Applied Polymer Science |
container_volume |
138 |
container_issue |
44 |
doi_str_mv |
10.1002/app.51314 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85108782114&doi=10.1002%2fapp.51314&partnerID=40&md5=4c6e54242bb99c5c962806f6e32851a5 |
description |
Conducting polymers are promising candidates for wearable devices due to mechanical flexibility combined with electroactivity. While electrochemical measurements have been adopted as a central transduction method in many on-skin sensors, less studied is the stability of the active materials (in particular poly3,4-ethylenedioxythiophene, PEDOT) in such systems, particularly for “on-skin” applications. In this study, several different variants of doped PEDOT are fabricated and characterized in terms of their (electrical, physical, and chemical) stability in biological fluid. PEDOT doped with tosylate (TOS) or polystyrenesulfonate (PSS) are selected as prototypical forms of conducting polymers. These are compared with a new variant of PEDOT co-doped with both TOS and PSS. Artificial interstitial fluid (aISF) loaded with 1% wt/vol bovine serum albumin is adopted as the testing medium to demonstrate the stability in dermal applications (i.e., conducting polymer microneedles or coatings on microneedles). A range of techniques such as cyclic voltammetry and electrochemical impedance spectroscopy are used to qualify and quantify the stability of the doped conducting polymers. Furthermore, this study is extended by using human skin lysate in the aISF to demonstrate proof-of-concept for stable use of PEDOT in wearable “on-skin” electronics. © 2021 The Authors. Journal of Applied Polymer Science published by Wiley Periodicals LLC. |
publisher |
John Wiley and Sons Inc |
issn |
218995 |
language |
English |
format |
Article |
accesstype |
All Open Access; Hybrid Gold Open Access |
record_format |
scopus |
collection |
Scopus |
_version_ |
1812871798757261312 |