Real-time power quality measurement audit of government building – A case study in compliance with IEEE 1159

Power Quality (PQ) measurements and auditing play a vital role for smart grid applications, industrial safety and reliability. The major electrical PQ characteristics and parameters, like Voltage Sags/Swells, Harmonic Distortion, Voltage Unbalance, Voltage Variation & Flicker, and Supply Interru...

Full description

Bibliographic Details
Published in:Acta IMEKO
Main Author: Ananth D.V.N.; Hannoon N.; Yunus M.S.B.M.; Jamaludin M.H.B.; Sameer Charavarthy V.V.S.S.; Chowdary P.S.R.
Format: Article
Language:English
Published: International Measurement Confederation (IMEKO) 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85153487955&doi=10.21014%2fACTAIMEKO.V12I1.1287&partnerID=40&md5=c3214bfdea7c970dcb9cfbce3046fad8
id 2-s2.0-85153487955
spelling 2-s2.0-85153487955
Ananth D.V.N.; Hannoon N.; Yunus M.S.B.M.; Jamaludin M.H.B.; Sameer Charavarthy V.V.S.S.; Chowdary P.S.R.
Real-time power quality measurement audit of government building – A case study in compliance with IEEE 1159
2023
Acta IMEKO
12
1
10.21014/ACTAIMEKO.V12I1.1287
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85153487955&doi=10.21014%2fACTAIMEKO.V12I1.1287&partnerID=40&md5=c3214bfdea7c970dcb9cfbce3046fad8
Power Quality (PQ) measurements and auditing play a vital role for smart grid applications, industrial safety and reliability. The major electrical PQ characteristics and parameters, like Voltage Sags/Swells, Harmonic Distortion, Voltage Unbalance, Voltage Variation & Flicker, and Supply Interruptions, are studied with the aim of maintaining the international or national standards. The electrical characteristics are studied and analyzed for single-phase and poly-phase systems in this IEEE 1159 recommended practice. The significant PQ constraints and parameters, like electromagnetic interference phenomenon deviation from the regular operation due to load equipment or source to load interaction, are described. Further, it is discussed PQ different monitoring devices, roles, and applications. In this paper, power quality monitoring of the equipment using FLUKE instrument and accessories to identify the equipment performance, audit, PQ issues are discussed practically for a two-panel boards switchgear equipment as a case study in Malaysia. Here, trends in voltage and current changes with current imbalances were observed on 1st May 2019 morning 8'o clock and on 7th May 2019 evening at 9'0 clock. © 2023 International Measurement Confederation (IMEKO). All rights reserved.
International Measurement Confederation (IMEKO)
0237028X
English
Article
All Open Access; Gold Open Access
author Ananth D.V.N.; Hannoon N.; Yunus M.S.B.M.; Jamaludin M.H.B.; Sameer Charavarthy V.V.S.S.; Chowdary P.S.R.
spellingShingle Ananth D.V.N.; Hannoon N.; Yunus M.S.B.M.; Jamaludin M.H.B.; Sameer Charavarthy V.V.S.S.; Chowdary P.S.R.
Real-time power quality measurement audit of government building – A case study in compliance with IEEE 1159
author_facet Ananth D.V.N.; Hannoon N.; Yunus M.S.B.M.; Jamaludin M.H.B.; Sameer Charavarthy V.V.S.S.; Chowdary P.S.R.
author_sort Ananth D.V.N.; Hannoon N.; Yunus M.S.B.M.; Jamaludin M.H.B.; Sameer Charavarthy V.V.S.S.; Chowdary P.S.R.
title Real-time power quality measurement audit of government building – A case study in compliance with IEEE 1159
title_short Real-time power quality measurement audit of government building – A case study in compliance with IEEE 1159
title_full Real-time power quality measurement audit of government building – A case study in compliance with IEEE 1159
title_fullStr Real-time power quality measurement audit of government building – A case study in compliance with IEEE 1159
title_full_unstemmed Real-time power quality measurement audit of government building – A case study in compliance with IEEE 1159
title_sort Real-time power quality measurement audit of government building – A case study in compliance with IEEE 1159
publishDate 2023
container_title Acta IMEKO
container_volume 12
container_issue 1
doi_str_mv 10.21014/ACTAIMEKO.V12I1.1287
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85153487955&doi=10.21014%2fACTAIMEKO.V12I1.1287&partnerID=40&md5=c3214bfdea7c970dcb9cfbce3046fad8
description Power Quality (PQ) measurements and auditing play a vital role for smart grid applications, industrial safety and reliability. The major electrical PQ characteristics and parameters, like Voltage Sags/Swells, Harmonic Distortion, Voltage Unbalance, Voltage Variation & Flicker, and Supply Interruptions, are studied with the aim of maintaining the international or national standards. The electrical characteristics are studied and analyzed for single-phase and poly-phase systems in this IEEE 1159 recommended practice. The significant PQ constraints and parameters, like electromagnetic interference phenomenon deviation from the regular operation due to load equipment or source to load interaction, are described. Further, it is discussed PQ different monitoring devices, roles, and applications. In this paper, power quality monitoring of the equipment using FLUKE instrument and accessories to identify the equipment performance, audit, PQ issues are discussed practically for a two-panel boards switchgear equipment as a case study in Malaysia. Here, trends in voltage and current changes with current imbalances were observed on 1st May 2019 morning 8'o clock and on 7th May 2019 evening at 9'0 clock. © 2023 International Measurement Confederation (IMEKO). All rights reserved.
publisher International Measurement Confederation (IMEKO)
issn 0237028X
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1825722581228978176