Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study; [Učinak sredstva za čišćenje zubne proteze na fizikalno-mehanička svojstva termoplastičnoga poliamidnog materijala za bazu proteze za injekcijsko prešanje: preliminarno istraživanje]

Objectives: This study aimed to assess the color stability, surface roughness, and flexural properties of the injection-molded thermoplastic polyamide Vertex ThermoSens denture base resin following a 3-minute immersion in Polident 3-minute denture cleanser. Methods: Sixty specimens (Vertex Ther-moSe...

Full description

Bibliographic Details
Published in:Acta Stomatologica Croatica
Main Author: Altarawneh H.M.; Alhajj M.N.; Salleh N.M.; Elkezza A.H.H.; Mahmood W.A.
Format: Article
Language:English
Published: University of Zagreb 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85180493697&doi=10.15644%2fasc57%2f4%2f4&partnerID=40&md5=3edb584271579c7db5ccf0d12116d48f
id 2-s2.0-85180493697
spelling 2-s2.0-85180493697
Altarawneh H.M.; Alhajj M.N.; Salleh N.M.; Elkezza A.H.H.; Mahmood W.A.
Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study; [Učinak sredstva za čišćenje zubne proteze na fizikalno-mehanička svojstva termoplastičnoga poliamidnog materijala za bazu proteze za injekcijsko prešanje: preliminarno istraživanje]
2023
Acta Stomatologica Croatica
57
4
10.15644/asc57/4/4
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85180493697&doi=10.15644%2fasc57%2f4%2f4&partnerID=40&md5=3edb584271579c7db5ccf0d12116d48f
Objectives: This study aimed to assess the color stability, surface roughness, and flexural properties of the injection-molded thermoplastic polyamide Vertex ThermoSens denture base resin following a 3-minute immersion in Polident 3-minute denture cleanser. Methods: Sixty specimens (Vertex Ther-moSens) were processed and divided into two main groups (n = 30) based on the type of test. Group 1 was further subdivided into two subgroups (n = 15): the control group immersed in distilled water (G1DW) and the test group immersed in Polident cleanser solution (G1PD). Group 2 was divided into three subgroups: a non-immersed group (G2None), a group immersed in distilled water (G2DW), and a group immersed in Polident cleanser solution (G2PD). Color change (∆E) and surface roughness measurements were conducted for group 1, and flexural modulus (E) test was performed for group 2. The CIE Labformula was utilized to calculate ∆E. An optical 3D surface analyzer and a three-point bending test were employed for surface roughness and E assessments, respectively. Data were subjected to statistical analysis using a paired-sample t-test for differences within each group before and after immersion. Furthermore, independent-sample t-tests and one-way ANOVA were conducted to analyze differences between groups. A significance level of P < 0.05 was considered. Results: The results revealed a slight, statistically insignificant (P > 0.05) ∆E in all color components (L*, a*, b*) after immersion in distilled water. However, after immersion in the denture cleanser, only the Lcomponent exhibited a statistically significant ∆E (P = 0.002), which was slight in magnitude. Addi-tionally, a significant difference was found in the ∆E between G1DW and G1PD, with G1PD showing a higher change (P = 0.007). A significant increase in surface roughness after immersion was observed in G1PD (P = 0.017), with a notable difference between G1DW and G Conclusion: Denture cleansers have the potential to modify the properties of thermoplastic polyamide resin. Further research is needed to explore the clinical implications of these observed changes on denture performance. 1PD. However, the E remained unaffected (P = 0.537). © 2023, University of Zagreb. All rights reserved.
University of Zagreb
17019
English
Article
All Open Access; Gold Open Access; Green Open Access
author Altarawneh H.M.; Alhajj M.N.; Salleh N.M.; Elkezza A.H.H.; Mahmood W.A.
spellingShingle Altarawneh H.M.; Alhajj M.N.; Salleh N.M.; Elkezza A.H.H.; Mahmood W.A.
Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study; [Učinak sredstva za čišćenje zubne proteze na fizikalno-mehanička svojstva termoplastičnoga poliamidnog materijala za bazu proteze za injekcijsko prešanje: preliminarno istraživanje]
author_facet Altarawneh H.M.; Alhajj M.N.; Salleh N.M.; Elkezza A.H.H.; Mahmood W.A.
author_sort Altarawneh H.M.; Alhajj M.N.; Salleh N.M.; Elkezza A.H.H.; Mahmood W.A.
title Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study; [Učinak sredstva za čišćenje zubne proteze na fizikalno-mehanička svojstva termoplastičnoga poliamidnog materijala za bazu proteze za injekcijsko prešanje: preliminarno istraživanje]
title_short Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study; [Učinak sredstva za čišćenje zubne proteze na fizikalno-mehanička svojstva termoplastičnoga poliamidnog materijala za bazu proteze za injekcijsko prešanje: preliminarno istraživanje]
title_full Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study; [Učinak sredstva za čišćenje zubne proteze na fizikalno-mehanička svojstva termoplastičnoga poliamidnog materijala za bazu proteze za injekcijsko prešanje: preliminarno istraživanje]
title_fullStr Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study; [Učinak sredstva za čišćenje zubne proteze na fizikalno-mehanička svojstva termoplastičnoga poliamidnog materijala za bazu proteze za injekcijsko prešanje: preliminarno istraživanje]
title_full_unstemmed Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study; [Učinak sredstva za čišćenje zubne proteze na fizikalno-mehanička svojstva termoplastičnoga poliamidnog materijala za bazu proteze za injekcijsko prešanje: preliminarno istraživanje]
title_sort Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study; [Učinak sredstva za čišćenje zubne proteze na fizikalno-mehanička svojstva termoplastičnoga poliamidnog materijala za bazu proteze za injekcijsko prešanje: preliminarno istraživanje]
publishDate 2023
container_title Acta Stomatologica Croatica
container_volume 57
container_issue 4
doi_str_mv 10.15644/asc57/4/4
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85180493697&doi=10.15644%2fasc57%2f4%2f4&partnerID=40&md5=3edb584271579c7db5ccf0d12116d48f
description Objectives: This study aimed to assess the color stability, surface roughness, and flexural properties of the injection-molded thermoplastic polyamide Vertex ThermoSens denture base resin following a 3-minute immersion in Polident 3-minute denture cleanser. Methods: Sixty specimens (Vertex Ther-moSens) were processed and divided into two main groups (n = 30) based on the type of test. Group 1 was further subdivided into two subgroups (n = 15): the control group immersed in distilled water (G1DW) and the test group immersed in Polident cleanser solution (G1PD). Group 2 was divided into three subgroups: a non-immersed group (G2None), a group immersed in distilled water (G2DW), and a group immersed in Polident cleanser solution (G2PD). Color change (∆E) and surface roughness measurements were conducted for group 1, and flexural modulus (E) test was performed for group 2. The CIE Labformula was utilized to calculate ∆E. An optical 3D surface analyzer and a three-point bending test were employed for surface roughness and E assessments, respectively. Data were subjected to statistical analysis using a paired-sample t-test for differences within each group before and after immersion. Furthermore, independent-sample t-tests and one-way ANOVA were conducted to analyze differences between groups. A significance level of P < 0.05 was considered. Results: The results revealed a slight, statistically insignificant (P > 0.05) ∆E in all color components (L*, a*, b*) after immersion in distilled water. However, after immersion in the denture cleanser, only the Lcomponent exhibited a statistically significant ∆E (P = 0.002), which was slight in magnitude. Addi-tionally, a significant difference was found in the ∆E between G1DW and G1PD, with G1PD showing a higher change (P = 0.007). A significant increase in surface roughness after immersion was observed in G1PD (P = 0.017), with a notable difference between G1DW and G Conclusion: Denture cleansers have the potential to modify the properties of thermoplastic polyamide resin. Further research is needed to explore the clinical implications of these observed changes on denture performance. 1PD. However, the E remained unaffected (P = 0.537). © 2023, University of Zagreb. All rights reserved.
publisher University of Zagreb
issn 17019
language English
format Article
accesstype All Open Access; Gold Open Access; Green Open Access
record_format scopus
collection Scopus
_version_ 1809677679808479232