Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay

This paper presents the experimental solutions for the influence of length to the behavior and settlement performance of stone column. Laboratory experiments were conducted to compare the results between the settlement performance of end bearing stone columns and floating stone columns. Unit cell co...

Full description

Bibliographic Details
Published in:Journal of Advanced Research in Applied Mechanics
Main Author: Azmi Y.I.; Nik Omar N.A.H.; Ng K.S.; Rashid A.S.A.; Mukri M.; Chew Y.M.
Format: Article
Language:English
Published: Semarak Ilmu Publishing 2025
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85217494047&doi=10.37934%2faram.132.1.6069&partnerID=40&md5=8f823b4b663f0dca88bc7929158ffc3f
id 2-s2.0-85217494047
spelling 2-s2.0-85217494047
Azmi Y.I.; Nik Omar N.A.H.; Ng K.S.; Rashid A.S.A.; Mukri M.; Chew Y.M.
Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay
2025
Journal of Advanced Research in Applied Mechanics
132
1
10.37934/aram.132.1.6069
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85217494047&doi=10.37934%2faram.132.1.6069&partnerID=40&md5=8f823b4b663f0dca88bc7929158ffc3f
This paper presents the experimental solutions for the influence of length to the behavior and settlement performance of stone column. Laboratory experiments were conducted to compare the results between the settlement performance of end bearing stone columns and floating stone columns. Unit cell concept is used to idealize the settlement performance of large column group under the uniform load. The parameters that investigated are the column length to diameter ratio. This experimental investigation used a small-scale unit cell model tank and investigated the column length of a single column. Furthermore, the physical test involved the use of a custom-made stone column model, constructed with a rectangular steel frame measuring 600 mm in height and 260*260 mm in length and width. The experiment incorporated three different column heights: 400 mm, 320 mm, and 240 mm. Additionally, three distinct area replacement ratios of 33%, 23% and 15% were employed in these testing experiments. The results indicated that an increase in the length of stone columns correlates with a reduction in settlement, together with the increase ability to dissipate excess water pressure leading to a faster consolidation rate. The settlement performance was compared with existing analytical solution where reasonable agreement was obtained. © 2025, Semarak Ilmu Publishing. All rights reserved.
Semarak Ilmu Publishing
22897895
English
Article
All Open Access; Gold Open Access
author Azmi Y.I.; Nik Omar N.A.H.; Ng K.S.; Rashid A.S.A.; Mukri M.; Chew Y.M.
spellingShingle Azmi Y.I.; Nik Omar N.A.H.; Ng K.S.; Rashid A.S.A.; Mukri M.; Chew Y.M.
Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay
author_facet Azmi Y.I.; Nik Omar N.A.H.; Ng K.S.; Rashid A.S.A.; Mukri M.; Chew Y.M.
author_sort Azmi Y.I.; Nik Omar N.A.H.; Ng K.S.; Rashid A.S.A.; Mukri M.; Chew Y.M.
title Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay
title_short Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay
title_full Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay
title_fullStr Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay
title_full_unstemmed Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay
title_sort Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay
publishDate 2025
container_title Journal of Advanced Research in Applied Mechanics
container_volume 132
container_issue 1
doi_str_mv 10.37934/aram.132.1.6069
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85217494047&doi=10.37934%2faram.132.1.6069&partnerID=40&md5=8f823b4b663f0dca88bc7929158ffc3f
description This paper presents the experimental solutions for the influence of length to the behavior and settlement performance of stone column. Laboratory experiments were conducted to compare the results between the settlement performance of end bearing stone columns and floating stone columns. Unit cell concept is used to idealize the settlement performance of large column group under the uniform load. The parameters that investigated are the column length to diameter ratio. This experimental investigation used a small-scale unit cell model tank and investigated the column length of a single column. Furthermore, the physical test involved the use of a custom-made stone column model, constructed with a rectangular steel frame measuring 600 mm in height and 260*260 mm in length and width. The experiment incorporated three different column heights: 400 mm, 320 mm, and 240 mm. Additionally, three distinct area replacement ratios of 33%, 23% and 15% were employed in these testing experiments. The results indicated that an increase in the length of stone columns correlates with a reduction in settlement, together with the increase ability to dissipate excess water pressure leading to a faster consolidation rate. The settlement performance was compared with existing analytical solution where reasonable agreement was obtained. © 2025, Semarak Ilmu Publishing. All rights reserved.
publisher Semarak Ilmu Publishing
issn 22897895
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1825722572962004992