Reliability, technical error of measurement and validity of height measurement using portable stadiometer
This study sought to examine the reliability and validity of height measurements using a portable stadiometer as compared to a mechanical scale. Samples from 142 adults aged 22 to 57 were taken during data collection in November 2014. There was a high degree of reliability for the inter-examiner, in...
發表在: | Pertanika Journal of Science and Technology |
---|---|
主要作者: | |
格式: | Article |
語言: | English |
出版: |
Universiti Putra Malaysia Press
2017
|
在線閱讀: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85021122709&partnerID=40&md5=69cdffd8e28c29b20a680b4b49bc61b3 |
id |
Baharudin A.; Ahmad M.H.; Naidu B.M.; Hamzah N.R.; Zaki N.A.M.; Zainuddin A.A.; Nor N.S.M. |
---|---|
spelling |
Baharudin A.; Ahmad M.H.; Naidu B.M.; Hamzah N.R.; Zaki N.A.M.; Zainuddin A.A.; Nor N.S.M. 2-s2.0-85021122709 Reliability, technical error of measurement and validity of height measurement using portable stadiometer 2017 Pertanika Journal of Science and Technology 25 3 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85021122709&partnerID=40&md5=69cdffd8e28c29b20a680b4b49bc61b3 This study sought to examine the reliability and validity of height measurements using a portable stadiometer as compared to a mechanical scale. Samples from 142 adults aged 22 to 57 were taken during data collection in November 2014. There was a high degree of reliability for the inter-examiner, intra-examiner and inter-instrument aspects with regards to mean difference, the inter correlation coefficient (ICC) and Bland-Altman Plot. For the inter-examiner aspect, the height measurement taken by the first examiner was 0.01 cm higher than that by the second examiner with an ICC of 0.999. For the intra-examiner aspect, the difference was 0.1 cm; this was higher in the first measurement compared to the second. The ICC was also 0.999. For the inter-instrument aspect, measurement taken by stadiometer was 0.61 cm higher than the measurement taken by mechanical scale and the ICC was 0.997. The Bland-Altman plot showed a distribution of differences between measurements in the inter-examiner, intra-examiner and inter-instrument aspects that were close to zero within the narrow range of ±1.96SD. The technical error of measurement (TEM), coefficient of reliability (R) and coefficient of variation (CV) for the inter-examiner, intra-examiner and inter-instrument aspects were within the acceptable limits. This study suggests that the portable stadiometer is reliable and valid for use in community surveys. © 2017 Universiti Putra Malaysia Press. Universiti Putra Malaysia Press 1287680 English Article |
author |
2-s2.0-85021122709 |
spellingShingle |
2-s2.0-85021122709 Reliability, technical error of measurement and validity of height measurement using portable stadiometer |
author_facet |
2-s2.0-85021122709 |
author_sort |
2-s2.0-85021122709 |
title |
Reliability, technical error of measurement and validity of height measurement using portable stadiometer |
title_short |
Reliability, technical error of measurement and validity of height measurement using portable stadiometer |
title_full |
Reliability, technical error of measurement and validity of height measurement using portable stadiometer |
title_fullStr |
Reliability, technical error of measurement and validity of height measurement using portable stadiometer |
title_full_unstemmed |
Reliability, technical error of measurement and validity of height measurement using portable stadiometer |
title_sort |
Reliability, technical error of measurement and validity of height measurement using portable stadiometer |
publishDate |
2017 |
container_title |
Pertanika Journal of Science and Technology |
container_volume |
25 |
container_issue |
3 |
doi_str_mv |
|
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85021122709&partnerID=40&md5=69cdffd8e28c29b20a680b4b49bc61b3 |
description |
This study sought to examine the reliability and validity of height measurements using a portable stadiometer as compared to a mechanical scale. Samples from 142 adults aged 22 to 57 were taken during data collection in November 2014. There was a high degree of reliability for the inter-examiner, intra-examiner and inter-instrument aspects with regards to mean difference, the inter correlation coefficient (ICC) and Bland-Altman Plot. For the inter-examiner aspect, the height measurement taken by the first examiner was 0.01 cm higher than that by the second examiner with an ICC of 0.999. For the intra-examiner aspect, the difference was 0.1 cm; this was higher in the first measurement compared to the second. The ICC was also 0.999. For the inter-instrument aspect, measurement taken by stadiometer was 0.61 cm higher than the measurement taken by mechanical scale and the ICC was 0.997. The Bland-Altman plot showed a distribution of differences between measurements in the inter-examiner, intra-examiner and inter-instrument aspects that were close to zero within the narrow range of ±1.96SD. The technical error of measurement (TEM), coefficient of reliability (R) and coefficient of variation (CV) for the inter-examiner, intra-examiner and inter-instrument aspects were within the acceptable limits. This study suggests that the portable stadiometer is reliable and valid for use in community surveys. © 2017 Universiti Putra Malaysia Press. |
publisher |
Universiti Putra Malaysia Press |
issn |
1287680 |
language |
English |
format |
Article |
accesstype |
|
record_format |
scopus |
collection |
Scopus |
_version_ |
1828987879649443840 |