Diagnostic Accuracy of Shear Wave Elastography as an Adjunct Tool in Detecting Axillary Lymph Nodes Metastasis
Objectives: This study evaluates the diagnostic performance of shear wave elastography (SWE) in differentiating between benign and axillary lymph node (ALN) metastasis in breast carcinoma. Materials and methods: Breast lesions and axillae of 107 patients were assessed using B-mode ultrasound and SWE...
出版年: | Academic Radiology |
---|---|
第一著者: | |
フォーマット: | 論文 |
言語: | English |
出版事項: |
Elsevier Inc.
2022
|
オンライン・アクセス: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85114250172&doi=10.1016%2fj.acra.2021.03.018&partnerID=40&md5=99e86cc56bb473eaf4649b0b5f85a511 |
id |
Ng W.L.; Omar N.; Ab Mumin N.; Ramli Hamid M.T.; Vijayananthan A.; Rahmat K. |
---|---|
spelling |
Ng W.L.; Omar N.; Ab Mumin N.; Ramli Hamid M.T.; Vijayananthan A.; Rahmat K. 2-s2.0-85114250172 Diagnostic Accuracy of Shear Wave Elastography as an Adjunct Tool in Detecting Axillary Lymph Nodes Metastasis 2022 Academic Radiology 29 10.1016/j.acra.2021.03.018 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85114250172&doi=10.1016%2fj.acra.2021.03.018&partnerID=40&md5=99e86cc56bb473eaf4649b0b5f85a511 Objectives: This study evaluates the diagnostic performance of shear wave elastography (SWE) in differentiating between benign and axillary lymph node (ALN) metastasis in breast carcinoma. Materials and methods: Breast lesions and axillae of 107 patients were assessed using B-mode ultrasound and SWE. Histopathology was the diagnostic gold standard. Results: In metastatic axillary lymph nodes, qualitative SWE using color patterns had the highest area under curve (AUC) value, followed by B-mode Ultrasound (cortical thickening >3 mm) and quantitative SWE using Emax of 15.2 kPa (AUC of 81.3%, 70.1%, and 61.2%, respectively). Qualitative SWE exhibited better diagnostic performance than the other two parameters, with sensitivity of 96.0% and specificity of 56.1%. Combination of B-mode Ultrasound (using cortical thickness of >3 mm as cut-off point) and qualitative SWE (Color patterns of 2 to 4) showed sensitivity of 71.6%, specificity of 95%, PPV of 96%, NPV of 66.7%, and accuracy of 80.4%. Conclusion: Qualitative SWE assessment exhibited higher accuracy compared to quantitative values. Qualitative SWE as an adjunct to B-mode ultrasound can further improve the diagnostic accuracy of metastatic ALN in breast cancer. © 2021 The Association of University Radiologists Elsevier Inc. 10766332 English Article |
author |
2-s2.0-85114250172 |
spellingShingle |
2-s2.0-85114250172 Diagnostic Accuracy of Shear Wave Elastography as an Adjunct Tool in Detecting Axillary Lymph Nodes Metastasis |
author_facet |
2-s2.0-85114250172 |
author_sort |
2-s2.0-85114250172 |
title |
Diagnostic Accuracy of Shear Wave Elastography as an Adjunct Tool in Detecting Axillary Lymph Nodes Metastasis |
title_short |
Diagnostic Accuracy of Shear Wave Elastography as an Adjunct Tool in Detecting Axillary Lymph Nodes Metastasis |
title_full |
Diagnostic Accuracy of Shear Wave Elastography as an Adjunct Tool in Detecting Axillary Lymph Nodes Metastasis |
title_fullStr |
Diagnostic Accuracy of Shear Wave Elastography as an Adjunct Tool in Detecting Axillary Lymph Nodes Metastasis |
title_full_unstemmed |
Diagnostic Accuracy of Shear Wave Elastography as an Adjunct Tool in Detecting Axillary Lymph Nodes Metastasis |
title_sort |
Diagnostic Accuracy of Shear Wave Elastography as an Adjunct Tool in Detecting Axillary Lymph Nodes Metastasis |
publishDate |
2022 |
container_title |
Academic Radiology |
container_volume |
29 |
container_issue |
|
doi_str_mv |
10.1016/j.acra.2021.03.018 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85114250172&doi=10.1016%2fj.acra.2021.03.018&partnerID=40&md5=99e86cc56bb473eaf4649b0b5f85a511 |
description |
Objectives: This study evaluates the diagnostic performance of shear wave elastography (SWE) in differentiating between benign and axillary lymph node (ALN) metastasis in breast carcinoma. Materials and methods: Breast lesions and axillae of 107 patients were assessed using B-mode ultrasound and SWE. Histopathology was the diagnostic gold standard. Results: In metastatic axillary lymph nodes, qualitative SWE using color patterns had the highest area under curve (AUC) value, followed by B-mode Ultrasound (cortical thickening >3 mm) and quantitative SWE using Emax of 15.2 kPa (AUC of 81.3%, 70.1%, and 61.2%, respectively). Qualitative SWE exhibited better diagnostic performance than the other two parameters, with sensitivity of 96.0% and specificity of 56.1%. Combination of B-mode Ultrasound (using cortical thickness of >3 mm as cut-off point) and qualitative SWE (Color patterns of 2 to 4) showed sensitivity of 71.6%, specificity of 95%, PPV of 96%, NPV of 66.7%, and accuracy of 80.4%. Conclusion: Qualitative SWE assessment exhibited higher accuracy compared to quantitative values. Qualitative SWE as an adjunct to B-mode ultrasound can further improve the diagnostic accuracy of metastatic ALN in breast cancer. © 2021 The Association of University Radiologists |
publisher |
Elsevier Inc. |
issn |
10766332 |
language |
English |
format |
Article |
accesstype |
|
record_format |
scopus |
collection |
Scopus |
_version_ |
1828987868854353920 |