Machine Parameters Estimation Using Closed - Loop Control Signal Curve Fitting

Apart from the current limits, the voltage limits will also affect the achievable performance of a motor drive. The voltage limits for a fault -tolerant drive will decide the maximum operating speed of the machine before flux weakening, hence the maximum attainable output power. Unlike current limit...

وصف كامل

التفاصيل البيبلوغرافية
الحاوية / القاعدة:2024 IEEE INDUSTRIAL ELECTRONICS AND APPLICATIONS CONFERENCE, IEACON 2024
المؤلفون الرئيسيون: Munim, Wan Noraishah Wan Abdul; Che, Hang Seng; Tousizadeh, Mandi; Baharom, Rahimi; Muhammad, Khairul Safuan; Rahmanl, Nor Farahaida Abdul
التنسيق: Proceedings Paper
اللغة:English
منشور في: IEEE 2024
الموضوعات:
الوصول للمادة أونلاين:https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001414140200021
author Munim
Wan Noraishah Wan Abdul; Che
Hang Seng; Tousizadeh
Mandi; Baharom
Rahimi; Muhammad
Khairul Safuan; Rahmanl
Nor Farahaida Abdul
spellingShingle Munim
Wan Noraishah Wan Abdul; Che
Hang Seng; Tousizadeh
Mandi; Baharom
Rahimi; Muhammad
Khairul Safuan; Rahmanl
Nor Farahaida Abdul
Machine Parameters Estimation Using Closed - Loop Control Signal Curve Fitting
Computer Science; Engineering
author_facet Munim
Wan Noraishah Wan Abdul; Che
Hang Seng; Tousizadeh
Mandi; Baharom
Rahimi; Muhammad
Khairul Safuan; Rahmanl
Nor Farahaida Abdul
author_sort Munim
spelling Munim, Wan Noraishah Wan Abdul; Che, Hang Seng; Tousizadeh, Mandi; Baharom, Rahimi; Muhammad, Khairul Safuan; Rahmanl, Nor Farahaida Abdul
Machine Parameters Estimation Using Closed - Loop Control Signal Curve Fitting
2024 IEEE INDUSTRIAL ELECTRONICS AND APPLICATIONS CONFERENCE, IEACON 2024
English
Proceedings Paper
Apart from the current limits, the voltage limits will also affect the achievable performance of a motor drive. The voltage limits for a fault -tolerant drive will decide the maximum operating speed of the machine before flux weakening, hence the maximum attainable output power. Unlike current limits, the voltage limits of the fault-tolerant drive depend on the machine parameters. Hence, an accurate machine parameter needs to be obtained to estimate the voltage variations under different fault scenarios. By using the measured currents and plugging it into the machine voltage equations, the theoretical voltages for the machine can be calculated using some initial values for the machine parameters. Accurate machine parameters can he obtained minimize the voltages. It by optimizing the machine parameters to theoretical voltage and the actual control is shown that the estimated machine parameters arc accurate enough to predict the control voltage references under varying operating conditions.
IEEE


2024


10.1109/IEACON61321.2024.10797442
Computer Science; Engineering

WOS:001414140200021
https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001414140200021
title Machine Parameters Estimation Using Closed - Loop Control Signal Curve Fitting
title_short Machine Parameters Estimation Using Closed - Loop Control Signal Curve Fitting
title_full Machine Parameters Estimation Using Closed - Loop Control Signal Curve Fitting
title_fullStr Machine Parameters Estimation Using Closed - Loop Control Signal Curve Fitting
title_full_unstemmed Machine Parameters Estimation Using Closed - Loop Control Signal Curve Fitting
title_sort Machine Parameters Estimation Using Closed - Loop Control Signal Curve Fitting
container_title 2024 IEEE INDUSTRIAL ELECTRONICS AND APPLICATIONS CONFERENCE, IEACON 2024
language English
format Proceedings Paper
description Apart from the current limits, the voltage limits will also affect the achievable performance of a motor drive. The voltage limits for a fault -tolerant drive will decide the maximum operating speed of the machine before flux weakening, hence the maximum attainable output power. Unlike current limits, the voltage limits of the fault-tolerant drive depend on the machine parameters. Hence, an accurate machine parameter needs to be obtained to estimate the voltage variations under different fault scenarios. By using the measured currents and plugging it into the machine voltage equations, the theoretical voltages for the machine can be calculated using some initial values for the machine parameters. Accurate machine parameters can he obtained minimize the voltages. It by optimizing the machine parameters to theoretical voltage and the actual control is shown that the estimated machine parameters arc accurate enough to predict the control voltage references under varying operating conditions.
publisher IEEE
issn

publishDate 2024
container_volume
container_issue
doi_str_mv 10.1109/IEACON61321.2024.10797442
topic Computer Science; Engineering
topic_facet Computer Science; Engineering
accesstype
id WOS:001414140200021
url https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001414140200021
record_format wos
collection Web of Science (WoS)
_version_ 1828987785517727744